How To

The Proper Methods for Using an AED on a Child

Finding out if a particular pair of child electrode pads or a built-in attenuator is needed to use the AED on a child is essential. Electrode pads designed for children function similarly to those intended for adults, allowing the AED to read the heart’s rhythm and, if necessary, assist in delivering a defibrillator’s life-saving shock.

The fundamental distinction is that the shock energy is attenuated (or “reduced”) from the average adult energy setting when the patient is a youngster. Typically, the power is reduced from the adult dose of 150 joules to the paediatric amount of 50 joules.

Attenuation may be integrated into an AED and actuated via a button, “key,” or other switching mechanisms. It may be pre-programmed into a separate set of paediatric electrode pads explicitly designed for young patients.

  • If your AED needs a different set of electrodes for a child, you must place those pads amid the emergency, turn on the device, and follow the voice prompts just as you would for an adult.
  • Switching to a child or paediatric mode is as simple as pressing a button if your AED pads may be used on adult and paediatric patients.

How to Use an AED on a Child?

  • Activate the AED and listen to the voice prompts.
  • Take off the patient’s upper shirt and ensure their chest is exposed and dry.
  • You can activate the AED’s child mode by pressing its child button or by using the AED’s child key.
  • If you have paediatric pads, attach them.
  • Anterior-posterior (or “front-and-back”) placement is the gold standard for attaching AED pads to a child, with one electrode pad in the centre of the chest and the other in the centre of the back.
  • Let the AED check the kid’s heart rate.
  • If the AED determines that a shock is necessary because the patient is in cardiac arrest, it will deliver the shock. Maintain a safe distance as the AED administers a defibrillation shock to the patient.
  • Start CPR and reevaluate the situation. AEDs are set up according to the standards set by the American Heart Association. In between each cardiac rhythm analysis by an AED, according to current AHA regulations, CPR should continue for two minutes. Take the AED’s instructions seriously.
  • When an AED is used, it is important to keep listening to the device until emergency medical services personnel come to take over the rescue.

If the automated external defibrillator (AED) or Reanimeren met LifePad does not detect a shockable rhythm, you should continue CPR until emergency personnel arrive, just as you would with an adult.

Conclusion

Most automated external defibrillators (AEDs) come with clear, voice-guided instructions. AED kopen, will help you in emergency paediatric situations. Two electrodes are placed on the victim’s skin, and the gadget is activated. This one is for the lower half of the body. The other is worn on the right side of the upper chest. However, the top pad must be removed from the pacemaker by at least an inch if one is visible.

 

To Top

Pin It on Pinterest